PDU Power Cords

PDU Power Cords supports continuous operation at high amperage loads without exceeding permissible conductor temperature rise. Oxygen-free copper conductors with low DC resistance ensure stable power transmission at rated current levels such as 16A, 20A, or 32A, depending on plug and conductor size. Cords are designed for minimal I²R losses, supporting full-load operation in high-density rack environments without performance degradation. 

Conductor Material

Oxygen-Free Annealed Copper (Class 5 as per IEC 60228)

Conductor Size Range

16 AWG to 12 AWG (1.31 mm² to 3.31 mm²)

Rated Voltage

250V AC (IEC 60320)

Rated Current

10A, 16A, 20A, or 32A depending on connector and cable size

Dielectric Withstand Voltage

2000V AC for 1 minute as per IEC 60320-1

Product Description

PDU Power Cord uses precision-machined IEC 60320 connectors with nickel-plated brass contacts to achieve consistent low-resistance mating. Surface finish, contact force, and spring geometry are optimized to reduce micro-arcing and thermal buildup at the insertion point, which is critical in continuous power applications. Contact resistance remains within 10 milliohms, minimizing localized heating. 

Insulation Resistance

≥100 MΩ at 500V DC

Temperature Rating

105°C continuous operating temperature (UL 758 and IEC 60227 compliance)

Flame Resistance

UL VW-1 and IEC 60332-1-2 compliant jacket

Connector Retention Force

≥50N (locking types as per IEC 60320-1)

Voltage Drop Limit

<2% over standard and extended lengths at full rated load

Shielding Option

Foil or Braided Shield with ≥85% coverage and drain wire termination

Insertion/Withdrawal Cycle Durability

≥10,000 cycles (mechanical endurance test)

Contact Resistance

≤10 milliohms at plug/socket interface

Jacket Material

PVC or TPE, RoHS-compliant, thermally stabilized

UL 817, CSA C22.2 No. 21, IEC 60320-1, EN 60320-1

UL 817, CSA C22.2 No. 21, IEC 60320-1, EN 60320-1

Technical Advantages

PDU Power Cord is engineered with conductor gauges selected to limit voltage drop to less than 2% across standard and extended lengths. For lengths exceeding 3 meters, conductor cross-sectional area is increased proportionally, maintaining voltage stability at equipment input terminals. This protects voltage-sensitive equipment from undervoltage-induced faults. 

PDU Power Cord integrates mechanical locking systems such as V-Lock, IEC Lock, or twist-lock plug variants to prevent unintentional disconnection. Plug retention force exceeds 50N as per IEC 60320-1 specifications, ensuring stable connectivity in environments subject to vibration or high cable tension. Retention reliability is validated through mechanical endurance testing exceeding 2000 mating cycles.

Let's Get Started

Need reliable Heat Sinks for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Industry Applications

Data Centers

Supports high-density rack deployments with stable voltage delivery and secure locking connectors in 24/7 mission-critical load environments. 

Telecommunication Hubs

Powers distributed network switches and routers, ensuring minimal EMI and voltage drop across long cable runs in relay stations. 

Industrial Automation Panels

Supplies consistent power to PLCs, motor drives, and HMIs with flame-retardant jackets and mechanical strain relief for vibration zones. 

Broadcast and Media Racks

Delivers isolated power to AV encoders, signal processors, and storage servers, minimizing signal interference through shielded cord configurations. 

Laboratory and Test Equipment

Provides clean power to sensitive instrumentation with low-leakage current and high dielectric strength for measurement repeatability and equipment safety. 

Medical Imaging Systems

Integrates with IEC-compatible power inputs on diagnostic devices, maintaining low contact resistance and high insulation reliability in clinical setups. 

 

Thermal Aging and Flame Resistance

PDU Power Cord insulation materials are tested per UL 1581 for thermal aging, maintaining dielectric properties after 10,000 hours at elevated temperature. Outer jackets are VW-1 flame rated and resist combustion propagation in enclosed spaces. This ensures suitability for use within hot aisles and cable-dense rack environments without compromising safety margins. 

PDU Power Cord is designed to support nonlinear load profiles typical in data center environments with high switching power supply densities. Stranding configuration and conductor inductance are controlled to minimize self-induced voltage distortion under harmonic-rich load conditions. This prevents cable-induced thermal derating in power delivery units. 

PDU Power Cords

Having Doubts? Our FAQ

Check all our Frequently Asked Question

How does Frigate ensure PDU Power Cord performance under continuous full-load current?

Frigate uses oxygen-free copper with controlled DC resistance to limit I²R losses. Each PDU Power Cord is tested at 100% rated current to ensure thermal rise stays within IEC 60227 limits. Cords are derating-free up to 40°C ambient. Conductors comply with UL 758 and IEC 60228 Class 5 standards. 

What testing does Frigate perform on the dielectric strength of its PDU Power Cords?

Frigate applies 2000V AC dielectric withstand testing for 60 seconds across conductors and ground. Leakage current is maintained below 0.5 mA during the test. All cords are tested per IEC 60320-1 and UL 817. High insulation resistance ensures safety under elevated humidity or conductive dust conditions. 

How does Frigate design PDU Power Cord for minimal voltage drop in high-density racks?

Frigate calculates conductor sizing using voltage drop formulas based on actual load, length, and temperature. For extended lengths, 12 AWG or larger wires are used to maintain <2% voltage drop. Power cords are terminated with low-resistance connectors. This ensures stable voltage at the IT equipment input. 

What connector retention features does Frigate implement to avoid disconnection in live racks?

Frigate offers IEC Lock, V-Lock, and twist-lock variants depending on PDU type and load profile. All PDU Power Cord connectors exceed 50N retention force as per IEC 60320-1. Each locking system is fatigue-tested for 2000 mating cycles. This prevents accidental disconnects during vibration, movement, or maintenance. 

How does Frigate ensure phase identification and load balance with PDU Power Cords?

Frigate offers color-coded jackets and custom-printed labels for L1, L2, and L3 phase mapping. This supports balanced load distribution in 3-phase PDU setups. It also reduces phase swapping errors during installation. Visual coding aligns with ANSI/TIA-942 structured cabling standards for data centers. 

Get Clarity with Our Manufacturing Insights

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

PDU Power Cords

Need reliable wires and cables for your next project? Get in touch with us today, and we’ll help you find exactly what you need!