UAE/Gulf Region Plug Power Cords

UAE/Gulf Region Plug Power Cords is manufactured with heat-resistant PVC compounds tested to ISO 188 Method B, ensuring insulation integrity after prolonged exposure to 100°C. This prevents surface cracking, embrittlement, and insulation failure in environments with sustained high ambient temperatures typical of the Gulf region. 

Rated Voltage

250V AC ±10%, 50 Hz

Rated Current

13A, 16A, or 20A depending on configuration

Conductor Type

Class 5 fine-stranded electrolytic copper, per IEC 60228

Conductor Resistance

≤1.5 Ω/km (for 1.5 mm²) at 20°C

Insulation Material

Heat-resistant PVC or TPE, thermal rating 105°C

Product Description

UAE/Gulf Region Plug Power Cord uses nickel- or tin-plated brass contacts, resistant to chloride-induced oxidation. Compliance with IEC 60068-2-11 salt mist testing confirms long-term contact reliability under coastal and industrial atmospheres with airborne sulfides and halogens. 

Sheath Tensile Strength

≥15 MPa, per IEC 60227-1

Flame Retardancy

UL94 V-0, IEC 60332-1 compliant

Dielectric Strength

2.5kV AC for 60 seconds without breakdown, per IEC 60227

Insulation Resistance

≥100 MΩ at 500V DC, per IEC 60227-2

Plug Pin Material

Brass, nickel or tin-plated, hardness ≥80 HV

Plug Pin Dimensions

Ø4.8 mm ±0.05 mm (BS 1363 compliance)

Glow Wire Test Temperature

850°C, per IEC 60695-2-11

Operating Temperature Range

−10°C to +105°C continuous

Salt Mist Resistance

96 hours exposure, per IEC 60068-2-11 (no corrosion observed)

≥6× outer diameter static, ≥10× outer diameter dynamic

≥6× outer diameter static, ≥10× outer diameter dynamic

Technical Advantages

UAE/Gulf Region Plug Power Cord passes dielectric strength tests at 2.5kV AC for 60 seconds with zero leakage, as per IEC 60227-1. This allows secure operation under grid conditions where overvoltages and switching transients exceed nominal values, preventing insulation puncture or arc initiation. 

UAE/Gulf Region Plug Power Cord supports steady-state currents up to 20A with conductor temperature rise limited to below 45K over ambient, aligning with IEC 60884-1 Clause 19. High-conductivity electrolytic copper and precision-molded contact zones minimize resistive heating during continuous load. 

 

Let's Get Started

Need reliable Heat Sinks for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Industry Applications

HVAC Systems

Used in high-current air conditioning units requiring 16A–20A plugs with heat-stabilized insulation and stable grounding for continuous load. 

Construction Equipment

Supports portable tools and temporary site boards exposed to dust, moisture, and mechanical stress under compliance with IP-rated assemblies and BS 1363. 

Telecom Infrastructure

Provides stable power to base transceiver stations and repeaters requiring low contact resistance and voltage fluctuation tolerance in desert climates. 

Oil and Gas Facilities

Used in control panels and monitoring devices exposed to corrosive atmospheres, requiring salt fog-resistant plating and thermal endurance above 100°C. 

Industrial Automation Systems

Connects to programmable logic controllers and drives with EMI-shielded variants for signal integrity and safe operation in noisy electrical environments. 

Medical Equipment

Powers diagnostic machines and lab instruments where strict dielectric integrity and flame-retardant material compliance to IEC 60601-1 are necessary. 

Flammability and Ignition Control

UAE/Gulf Region Plug Power Cord materials meet UL94 V-0 classification and conform to IEC 60332-1 flame propagation limits. Plug housings resist ignition under 850°C glow-wire testing, reducing fire propagation risk in fault or overload scenarios within enclosed spaces. 

UAE/Gulf Region Plug Power Cord exhibits plug pin-to-socket contact resistance <15 mΩ, verified through micro-ohm measurement under IEC 62196 test regime. Stable contact pressure and surface treatment ensure minimal energy loss at the interface, supporting high-efficiency power transfer. 

UAE/Gulf Region Plug Power Cords

Having Doubts? Our FAQ

Check all our Frequently Asked Question

How does Frigate ensure mechanical strength of UAE/Gulf Region Plug Power Cord under repeated flexing?

Frigate tests each UAE/Gulf Region Plug Power Cord using IEC 60227-2 flexing tests with over 10,000 bend cycles. The strain relief is designed to maintain cable retention force above 60N during axial pulls. High-flex PVC or TPE compounds with elongation ≥200% are selected to avoid insulation cracks. This guarantees long-term durability in industrial and mobile equipment. 

How does Frigate verify conductor resistance in UAE/Gulf Region Plug Power Cord?

Frigate measures conductor resistance using four-point Kelvin testing to ensure values stay within IEC 60228 limits. Class 5 fine copper strands are used to minimize resistive losses during high current transfer. Every production batch includes sampling for DC resistance per meter. This ensures efficient current flow and controlled heat rise under full load. 

What type of flame testing does Frigate apply to UAE/Gulf Region Plug Power Cord?

Frigate conducts IEC 60332-1 and glow wire testing at 850°C on plug materials. Only V-0 rated compounds are used to resist ignition and limit flame spread. Flame propagation is measured to confirm self-extinguishing properties within 60 seconds and ≤50mm char length. This helps meet fire safety standards in enclosed and heat-sensitive environments.

How does Frigate ensure stable electrical contact over plug lifetime?

Frigate applies silver or nickel plating on plug pins to reduce contact resistance over repeated insertion cycles. Contact surfaces are tested for micro-ohm resistance stability across 5,000 insertions. Plug geometry is controlled to within ±0.05mm to ensure tight socket fit. This reduces arcing, overheating, and long-term degradation in UAE socket systems. 

What insulation testing does Frigate perform on UAE/Gulf Region Plug Power Cord?

Frigate tests insulation resistance at 500V DC per IEC 60227 standards, targeting values above 100 MΩ. Power cords are also subjected to high-voltage withstand testing at 2.5kV AC for 60 seconds. This confirms dielectric strength of both core insulation and overall sheath. Such testing ensures no leakage, even under Gulf region humidity and voltage stress. 

Can the UAE/Gulf Region Plug Power Cord handle extreme Gulf temperatures without early failure?
  • Uses heat-resistant PVC/TPE compounds rated for 105°C continuous operation. 
  • Tested for prolonged heat exposure without surface cracking or embrittlement. 
  • Maintains insulation integrity and flexibility in desert climate conditions. 
  • Withstands continuous load without thermal deformation of plug housing. 
  • Prevents insulation hardening over years of high-temperature service. 
  • Retains electrical and mechanical properties even in direct sun exposure. 
How well does it maintain consistent conductivity under high current loads?
  • Made with high-conductivity electrolytic copper for reduced energy loss. 
  • Fine-stranded construction improves current distribution and flexibility. 
  • Precision-molded contact zones ensure uniform pressure and stable connection. 
  • Low micro-ohm contact resistance reduces power wastage during transfer. 
  • Minimizes resistive heating under prolonged heavy load conditions. 
  • Supports continuous operation at up to 20A without exceeding safe temperature rise. 
Is it suitable for reliable performance in coastal and industrial atmospheres?
  • Nickel or tin-plated brass pins protect against surface oxidation. 
  • Designed to withstand corrosive airborne salts and sulfides. 
  • Maintains low contact resistance even after long-term exposure. 
  • Resists degradation from humidity and temperature fluctuations. 
  • Stable operation in facilities near sea or chemical processing areas. 
  • Protects against pitting and surface damage that could impair conductivity. 
What ensures long-term mechanical strength in mobile or industrial use?
  • Cable passes flex testing for over 10,000 bend cycles without failure. 
  • Strain relief engineered to hold cable securely under axial pull forces. 
  • Flexible insulation compounds with elongation ≥200% resist cracking. 
  • Outer sheath maintains tensile strength under frequent movement. 
  • Internal conductor stranding designed to resist metal fatigue. 
  • Suitable for repeated winding, unwinding, and repositioning in the field. 
How does it reduce fire risk in enclosed or high-heat environments?
  • Flame-retardant materials self-extinguish rapidly after ignition source removal. 
  • Glow-wire tested at 850°C to prevent ignition from overheated parts. 
  • Limits flame spread to ≤50mm to contain fire hazard. 
  • Reduces smoke emission in the event of overheating or short-circuit. 
  • Maintains structural integrity longer during thermal incidents. 
  • Provides added protection in areas with limited ventilation. 
Get Clarity with Our Manufacturing Insights

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

UAE/Gulf Region Plug Power Cords

Need reliable wires and cables for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Get Latest Price

Get Price Form

UAE/Gulf Region Plug Power Cords

Need reliable Machining for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Get Latest Price

Get Price Form