High-Performance Electrical Components for Oil & Gas

Frigate designs electrically robust solutions engineered for thermal extremes, corrosive media, and hazardous zones in oil and gas environments. 

Oil and Gas

Engineered with FEP, PFA, and thermoset jackets to withstand hydrogen sulfide, hydrocarbon vapors, and salt-laden environments. 

Triple-insulated designs with anti-static sheaths and flame-blocking fillers prevent ignition risks in volatile oil and gas zones. 

Cables maintain insulation integrity from –65°C to +200°C using PEEK, XLPE, and silicone for thermal shock resilience. 

Future-Ready Electrical Solutions

Partner with Frigate to implement advanced electrical technologies enabling high-voltage endurance system reliability and future-ready industrial power architectures. 

Electrical Components We Manufacture

From Cables & Wires to Transformers, Our Electrical Products power your projects across industries. Browse below to find what suits your needs.

Potential Transformers (PTs) - IMG (2)
Isolation Transformers - IMG (2)
Flat Series _ UI Transformers - IMG (2)
Lighting Transformers - IMG (2)
Cast Resin Transformers - IMG (3)
Medical-Grade Transformers - IMG
Toroidal Transformers - IMG
EI _ Laminated Core Transformers - IMG (3)
Buck-Boost Transformers - IMG (3)
Planar Transformers - IMG
Danish Plug Power Cord - IMG (2)
PDU Power Cord - IMG (2)
Type B NEMA Power Cords - IMG (4)
Type N Power Cords (2)
Australian Plug Power Cord - IMG (3)
Type L Power Cords (4)
UAEGulf Region Plug Power Cord - img (5)
Locking Power Cord - IMG
Type E Power Cords (2)
Type A NEMA Power Cords - IMG (2)
3-Phase Sine Wave Filter Inductor (2)
Air Core Inductor
Inverter Isolation Choke - img
RL Load Reactor (3)
Saturable Reactor
Auxiliary Inductor (2)
Output Choke (3)
power factor correction choke - IMG
Power Smoothing Reactor (2)
Boost Converter Filter Inductor (3)

In Their Words

Endorsed by industry decision makers who value our streamlined procurement and efficient execution.

Words from Clients

See how global OEMs and sourcing heads describe their experience with our scalable execution.

Industrial-Grade Electrical Systems for Oil & Gas Operations

High-durability cables support power and signal delivery across drilling modules, risers, and living quarters under extreme marine and mechanical conditions. 

Subsea Equipment Interfaces

Cable systems withstand hydrostatic pressure, chemical ingress, and flex fatigue, ensuring uninterrupted control of blowout preventers, umbilicals, and ROV systems. 

Modular Skid Interconnects

Multi-core armored cables route power and control signals through pressurized enclosures and tray systems across dynamic offshore modules. 

oil & gas

Bend Radius Engineering

Frigate cables feature reduced outer diameter geometry and tight-tolerance concentricity to achieve bend radii as low as 6×OD. 

High-Stress Installation Performance

Shear-resistant fillers and low-friction jackets enable tray pulls exceeding 100 meters without conduit lubrication under tensile loads over 1000 N.

Abrasion and Flame Resistance

Thermoplastic jacket compounds offer enhanced abrasion control, while vertical flame resistance ensures integrity in heat-intensive tray stacks.

Precision Electrical Systems for Every Industry

Built for demanding sectors, our electric products offer accurate voltage regulation, thermal stability, and EMI shielding—customized for Oil and Gas applications. 

Rigorous Validation in Oil and Gas Transformers

Frigate engineers transformers for oil and gas operations with testing measures designed for extreme environments, operational continuity, and uncompromised safety. 

Explosion-Proof Validation
Enclosures and insulation systems are tested under high-pressure conditions to eliminate ignition risks in hazardous classified environments.
Load Cycle
Endurance
Transformers undergo repetitive high-load cycling simulations to validate stability, reliability, and efficiency in heavy-duty continuous operations.
Environmental Stress Testing
Salt fog, humidity, and thermal shock assessments ensure consistent transformer performance across offshore and desert field applications.

Electrical Market Insights

Explore how advanced insulation and dielectric technologies are redefining reliability in modern industrial power systems. 

Having Doubts? Our FAQ

Check all our Frequently Asked Questions

How does Frigate prevent cable failure due to chloride-induced corrosion in offshore environments?

Frigate uses AISI 316L stainless steel and nickel-alloy armoring to resist pitting and crevice corrosion from saline spray and condensates. These materials maintain structural integrity under long-term UV and humidity exposure. Jackets are compounded with halogen-free thermoplastics tested against salt fog per ASTM B117. This enables reliable deployment on FPSOs and open-deck drilling platforms. 

How does Frigate ensure signal stability in high-frequency instrumentation under heavy EMI?

Frigate designs its instrumentation cables with individually shielded pairs, combined with 90%+ coverage tinned copper braid. Impedance is matched within ±10% for RS-485, HART, and Modbus protocols. Dielectric materials are selected for low permittivity to reduce signal distortion. This construction minimizes common-mode noise in dense control cabinets and long tray runs. 

What construction features does Frigate use to enhance flex life in dynamic rig environments?

Frigate employs helical lay fine-stranded conductors and anti-wicking fillers for torsional resilience. Cable cores are reinforced with aramid yarns and elastomeric binders to resist fatigue. Testing includes up to 10 million flex cycles under temperature and tension loads. This ensures consistent electrical continuity in drag chains and articulating booms. 

How are Frigate’s cables adapted for high-temperature process areas in refineries?

Frigate uses silicone rubber and mica-glass insulation rated to 200°C for continuous exposure. These materials maintain dielectric strength and physical stability under radiant heat and thermal cycling. Outer sheaths are formulated to resist softening or cracking near flare stacks and steam lines. Cable life is verified through accelerated thermal aging tests. 

How does Frigate support long cable pulls in multi-tier cable trays?

Cables are designed with low-friction, high-abrasion resistant jackets that enable tray pulls up to 100 meters without lubricant. Concentric core geometry ensures consistent outer diameter for smooth bends. Fillers resist shear and maintain shape under sidewall pressure. This design improves installation time and reduces mechanical damage during routing. 

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

Loading....