Electric Motor Driven Pump Skids

Inconsistent pressure or flow can disrupt critical operations, especially in continuous processing or transfer lines. Our Electric Motor Driven Pump Skids handle 1 m³/h to 2,000 m³/h with heads up to 500 meters, offering flexibility across various plant requirements.

Flow Rate Range

1 m³/h to 2,000 m³/h (4.4 GPM to 8,800 GPM) – Customizable for process requirements

Pressure/Head Capacity

10 to 500 meters (33 to 1,640 ft) – Multi-stage designs available

Power Requirements

0.75 kW to 1,000 kW (1 HP to 1,340 HP) – 3-phase, 380-480V/690V, 50/60Hz, VFD standard

Materials of Construction

Pump Housing: Cast Iron, SS 316, Duplex Skid Frame: Carbon Steel (painted/SS)

Fluid Compatibility

Water, Chemicals, Oils, Process Fluids – Material-dependent (PTFE-lined options)

Product Description

You can choose from VFD-controlled motors, multi-stage designs, and corrosion-resistant housings to match each site condition. We supply fully integrated skid units that reduce installation time and eliminate downstream compatibility concerns.

Temperature Range

-40°C to 250°C (-40°F to 482°F) – High-temp models with cooling jackets

Connection Types & Sizes

Flanged (ANSI/DIN), Tri-Clamp (sanitary) – Sizes: 25 mm to 400 mm (1″ to 16″)

Mounting Configuration

Modular Skid (Horizontal)

Seal System

Mechanical Seal (SiC/TC), Mag Drive, or Packing Gland – API Plan 11/52 support

Efficiency Rating

80% to 95% – IE3/IE4 motors with optimized hydraulics

NPSH Required

2 m to 8 m (6.5 ft to 26 ft) – Critical for high-speed pumps

Speed Range

900 RPM to 3,600 RPM – VFD-controlled for variable flow

Solids Handling Capability

≤5% solids by weight – Hardened materials for abrasive slurries

Certifications & Standards

ATEX, PED, API 610, ISO 9001 – CE/UL certified control panels

Operating Noise Level

< 75 dB(A) – Acoustic enclosures available (reduces to <65 dB)

Coupling System

Flexible Spacer Coupling (API 671) – Laser-aligned for vibration control

Technical Advantages

Flow rate instability or pressure drops reduce downstream process efficiency. Our pump skids use IE3 or IE4 motors, delivering 80% to 95% operating efficiency even in fluctuating line conditions. 
NPSH compatibility from 2 to 8 meters allows high-speed operation without cavitation, which protects seals and impellers during long hours. Each unit can include acoustic enclosures for sound levels below 75 dB(A), with options to lower it under 65 dB for enclosed facilities. 

Let's Get Started

Need reliable Flanges for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Industry Applications

Chemical Process Plants

Handles corrosive fluids and variable pressures using SS 316 or duplex materials with flexible motor sizing.

Cooling Water Circuits

Supplies steady circulation across exchangers with thermal range from -40°C to 250°C and VFD motor support.

Pharmaceutical & Sanitary Lines

Meets CIP compliance with tri-clamp fittings and stainless internals, suitable for filtered process fluids.

Oil Transfer Systems

Works with medium-viscosity or low-NPSH setups using mag drive or mechanical seals and abrasion-resistant coatings.

Power Generation Units

Feeds condensate, boiler, or jacket water lines with skid-mounted motors rated up to 1,000 kW.

Pulp and Paper Industry

Handles slurry or semi-solid flow below 5% solid load using hardened impeller materials and flexible coupling systems.

Electric Motor Driven Pump Skids

Pump Skids Engineered for Performance Integration

These units support process stability by offering customized build-ups based on your plant utility grid, temperature limits, and fluid properties. We deliver each system with test data, material traceability, and GA drawings to support pre-approval and standardization across future projects. 
Our engineering team adjusts seals, cooling jackets, and inlet designs based on your job-specific needs, helping avoid unexpected retrofits. For sourcing teams focused on reliability and delivery alignment, these skids minimize downstream corrections and long-term downtime. 

Electric Motor Driven Pump Skids

Having Doubts? Our FAQ

Check all our Frequently Asked Question

Can you match the pump skid to our existing plant utility and fluid properties?

Yes, we configure motor voltage, frequency, and VFD compatibility based on your plant’s electrical specs. Fluid properties such as viscosity, corrosiveness, and temperature are reviewed before material selection. We also modify the seal system and pipe routing to avoid mismatch issues during installation. 

 

How do you support us in selecting the right motor and pump combination?

We assess your required flow rate, head, and duty cycle to decide between single or multi-stage designs. Based on power availability, we size motors from 0.75 kW to 1,000 kW with IE3/IE4 efficiency. If needed, we simulate different duty points to avoid oversizing or running losses.

What level of documentation do you provide before final order confirmation?

We share detailed GA drawings, P&ID layouts, motor specs, and component datasheets for review. You can validate clearances, nozzle orientation, and access zones before approval. This helps eliminate any surprises during site integration or skid anchoring.

Can we customize the materials for specific chemical or temperature exposure?

Yes, we offer wetted parts in SS 316, duplex, or PTFE-lined options based on chemical resistance charts. For high-temperature service, we apply cooling jackets or heat-resistant insulation on components. Each selection is made based on actual fluid test data or process input from your side.

How do you handle noise, vibration, or skid balance for sensitive plant environments?

We offer acoustic enclosures and below-75 dB(A) configurations for indoor use or compliance zones. Spacer couplings with laser alignment reduce vibration and extend bearing life. We also test dynamic balancing and base grouting layout to avoid uneven skid performance post-installation.

Get Clarity with our Manufacturing Insights

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Global Sales Office

818, Preakness lane, Coppell, Texas, USA – 75019

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

Electric Motor Driven Pump Skids

Need reliable wires and cables for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Get Latest Price

Get Price Form

Electric Motor Driven Pump Skids

Need reliable Machining for your next project? Get in touch with us today, and we’ll help you find exactly what you need!

Get Latest Price

Get Price Form