Transformers for Telecom Industry

Frigate’s telecom-grade transformers deliver consistent performance under fluctuating voltage, supporting continuous uptime in communication networks. 

Transformers for Telecom Industry

Built to maintain signal voltage during peak data transmission cycles using balanced magnetic coupling and reduced parasitic losses. 

Equipped with thermally stable cores and reinforced insulation to ensure extended operation in enclosed or ventilated outdoor cabinets. 

Available in toroidal and planar formats, our designs preserve required creepage and clearance per IEC and Telcordia standards. 

Our Clients

Preferred by OEMs and system designers for transformer sourcing

Our Products

Browse our transformer lineup built to support diverse voltage, insulation, and mounting needs across industries.

All
Specialty Application Transformers
Power Transformers
Isolation & Safety Transformers
Instrument Transformers
High-Frequency & Switching Transformers
Core Type Transformers
Cooling & Construction Type Transformers
Lighting Transformers - IMG (2)
Current Transformers (CTs) - IMG (3)
Toroidal Transformers - IMG
Multi-Winding Transformers - img (2)
Cast Resin Transformers - IMG (3)
Buck-Boost Transformers - IMG (3)
Flat Series _ UI Transformers - IMG (2)
Pulse Transformers - IMG
Potential Transformers (PTs) - IMG (2)
Amorphous Core Transformers - IMG
Load More

Feedback from Transformer Clients

Hear how procurement teams and engineering leads rate our transformer reliability, customization depth, and production consistency.

Words from Clients

See how global OEMs and sourcing heads describe their experience with our scalable execution.

Transformer Integration in Telecom Systems

Telecom transformers enable regulated voltage and system isolation in base stations, repeaters, and digital switching systems. We engineer these to align with ETSI, GR-1089-CORE, and thermal derating requirements for outdoor and indoor network nodes. 

Cellular Base Stations

Provides isolation for rectifier modules and consistent power for RRH, DU, and BBU units with high EMI suppression. 

Signal Processing Units

Supports isolation of analog front ends and DSP modules with low-loss windings that reduce voltage noise and crosstalk. 

Transformers for Telecom Industry
Transformers for Telecom Industry
Transformers for Telecom Industry

Tailored Power Transformer Designs

Frigate provides application-specific transformer designs that simplify system layout while meeting telecom environmental ratings. 

Mounting and Pinout Flexibility

We support through-hole and surface-mount formats, configurable pinout, and bracket designs for rack, pole, or wall-mount units.

Platform-Centric Integration

Our transformers integrate into power conversion blocks, EMI filters, or voltage conditioning units across hybrid and digital telecom platforms.

Full-Spectrum Transformer Solutions

Engineered for high-reliability environments, our Telecom transformers deliver precise voltage regulation, low leakage current, and superior EMI suppression.

Telecom Transformers Tested for Network Reliability

Frigate conducts extensive testing on telecom-grade transformers to ensure consistent performance, safety, and durability in critical communication systems. Each unit undergoes electrical, thermal, and mechanical verification processes that replicate real-world operating conditions for network hardware. 

Dielectric Strength & Insulation Resistance
Validates isolation integrity and insulation quality under high-voltage stress conditions to prevent breakdown during continuous telecom operation.
Thermal Endurance & Load Cycling
Assesses temperature stability and winding integrity through repeated load cycles and extended high-temperature exposure.
EMI Suppression & Signal Integrity
Measures electromagnetic interference control and verifies minimal impact on sensitive network signal paths.

Insights from Transformer Manufacturing Experts

Read technical articles on transformer integration, compliance standards and sourcing strategies across industry-specific use cases.

Having Doubts? Our FAQ

Check all our Frequently Asked Questions

How does Frigate design transformers for outdoor telecom enclosures with thermal stress?

Frigate selects low-loss ferrite or amorphous cores to reduce heat generation under continuous power delivery. High-temperature Class H insulation prevents dielectric degradation in ventilated and sealed housings. Windings are arranged to support natural convection and minimize thermal gradients. Each design undergoes thermal profiling to validate endurance under outdoor ambient conditions and load peaks. 

 

What EMI mitigation techniques does Frigate apply in transformers for telecom networks?

Frigate uses segmented windings, electrostatic shielding, and optimized bobbin geometry to minimize conducted and radiated EMI. Core materials are selected for low stray flux and reduced hysteresis. Layout design considers isolation zones and filter paths. All EMI performance is verified through testing per GR-1089-CORE or equivalent regional telecom EMC requirements. 

How does Frigate support mechanical integration in compact telecom rack or pole-mounted units?

Frigate offers mechanical formats including toroidal, planar, and encapsulated geometries with tailored mounting flanges or brackets. Terminal blocks, pin headers, or flying leads can be specified based on enclosure constraints. Windings are routed for optimal lead dress and strain relief. Each configuration is reviewed against available chassis dimensions and airflow limitations. 

What validation steps does Frigate follow to ensure transformer reliability in telecom base stations?

Each transformer is tested for dielectric strength, insulation resistance, and short-term overcurrent tolerance. Frigate uses real-world load simulations and thermal cycling to assess degradation thresholds. Validation data includes EMI suppression efficiency and long-term voltage regulation. All manufacturing follows telecom-grade QA systems and traceability frameworks. 

Can Frigate configure voltage profiles and winding structures for hybrid telecom platforms?

Frigate customizes primary-to-secondary turns ratios, tap positions, and interwinding insulation based on input-output voltage demands. Designs support single, dual, or multi-output configurations with low interwinding capacitance for signal-sensitive systems. Transformer layouts are adapted to fit AC-DC, DC-DC, or standby modules in converged hybrid deployments.

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

Loading....