Electrical Equipments for Data Center

Frigate delivers engineered electrical solutions that uphold performance, reliability, and thermal resilience in high-density, high-availability data center environments. 

data center

High-conductivity copper cables with XLPE/EPR insulation maintain ampacity and thermal stability in confined, high-temperature data center environments.

Shielded cable assemblies with >90% coverage suppress differential-mode noise, ensuring signal integrity in high-frequency, interference-prone environments.

Laminated bus bars support 2N redundancy, low contact resistance, and safe rack-level expansion with arc-flash mitigation and thermal tolerance. 

Future-Ready Electrical Solutions

Partner with Frigate to implement advanced electrical technologies enabling high-voltage endurance system reliability and future-ready industrial power architectures. 

Electrical Components We Manufacture

From Cables & Wires to Transformers, Our Electrical Products power your projects across industries. Browse below to find what suits your needs.

Potential Transformers (PTs) - IMG (2)
Control Transformers - IMG (4)
Step-Down Transformers - IMG
Medical-Grade Transformers - IMG
UPS & Inverter Transformers - IMG (3)
Step-Up Transformers - IMG (2)
Ferrite Core Transformers - IMG (3)
Isolation Transformers - IMG (2)
Three-Phase Transformers - IMG (1)
SMPS High-Frequency Transformers - IMG (3)
EV AC Charging Cord - IMG (2)
Danish Plug Power Cord - IMG (2)
GB_T EV Charging Cord - IMG (2)
DC to USB Power Cord - IMG
UK Plug Power Cord - IMG
Type B NEMA Power Cords - IMG (4)
DC Barrel Power Cord - IMG
Type M Power Cords
Type K Power Cords
Locking Power Cord - IMG
3-Phase Sine Wave Filter Inductor (2)
Power Smoothing Reactor (2)
3-Phase Output Choke - IMG (2)
RL Load Reactor (3)
Detuned Reactor (2)
Harmonic Filter Choke
DC Reactor (3)
Boost Converter Choke
Boost Converter Filter Inductor (3)
power factor correction choke - IMG

In Their Words

Endorsed by industry decision makers who value our streamlined procurement and efficient execution.

Words from Clients

See how global OEMs and sourcing heads describe their experience with our scalable execution.

Load Path Implementation of Electrical Systems in Data Centers

Data center electrical infrastructure operates under continuous high-load, high-temperature, and space-constrained conditions, introducing thermal and mechanical stress. Components must comply with IEC 61439, ANSI/TIA-942, and Uptime Tier standards for dielectric strength, EMC, and fault-tolerant power continuity. 

Core Power Distribution Backbone

Delivers high-current power from switchgear to PDUs using low-impedance bus bars and thermal-rated cables with high ampacity and flame retardance. 

Rack-Level Power and Signal Routing

Supports dense rack configurations with pre-terminated LSZH cables and shielded assemblies ensuring minimal signal degradation and efficient thermal dissipation. 

data center

Pre-Terminated Harnessing

Frigate delivers pre-terminated electrical harnesses with serialized endpoints, ensuring mechanical integrity, reduced installation time, and audit-ready documentation. 

Serialized Cable Assemblies

Each harness features heat-shrink labeled endpoints, verified connector torque, and is factory-tested for continuity, insulation resistance, and dielectric strength.

Installation and Documentation

Harnesses are delivered with 3D routing diagrams and embedded QR codes for each unit, enabling streamlined installation, configuration accuracy, and long-term maintainability.

Precision Electrical Systems for Every Industry

Built for demanding sectors, our electric products offer accurate voltage regulation, thermal stability, and EMI shielding—customized for Data Center applications. 

Transformer Quality Assurance for Data Center Infrastructure

Data centers cannot afford even milliseconds of power instability. Frigate ensures transformer quality through advanced validation, precision monitoring, and rigorous stress testing to meet uptime-critical demands. 

Thermal Endurance Testing
Transformers undergo accelerated heat cycle testing to validate insulation stability and winding reliability under continuous high-load data center operations.
Harmonic Load Simulation
Full-load harmonic simulations replicate nonlinear server demand to ensure transformers maintain efficiency, power factor, and harmonic distortion limits.
Partial Discharge
Analysis
Online PD monitoring ensures insulation integrity by detecting micro-failures early, preventing cascading breakdowns and costly downtime.

Electrical Market Insights

Explore how advanced insulation and dielectric technologies are redefining reliability in modern industrial power systems. 

Having Doubts? Our FAQ

Check all our Frequently Asked Questions

How does Frigate ensure dielectric strength in high-voltage data center cable assemblies?

Frigate conducts high-potential (hipot) testing on all insulated conductors to verify dielectric breakdown voltage under stress. Cables are insulated with XLPE or EPR compounds rated for elevated temperatures and partial discharge resistance. Conductor separation and insulation wall thickness are designed per IEC 60287 and UL 1581 guidelines. This ensures safe operation under sustained voltage stress in dense cable tray environments. 

 

What makes Frigate’s bus bar systems suitable for high-load, fault-tolerant power zones?

Frigate manufactures laminated and extruded bus bars with current ratings up to 4000 A and surface resistivity below 0.2 µΩ. Tap-off points are engineered for arc containment using segregated phase barriers and touch-safe insulation. Thermal expansion gaps and bolted joints allow mechanical stability under high load cycles. The systems are designed for compliance with IEC 61439-2 in Tier-certified power architectures. 

How does Frigate validate connector torque and mechanical integrity in pre-terminated harnesses?

Each connector is torque-calibrated using programmable digital torque tools with tolerance logging. Frigate maintains mechanical pull-force validation per ANSI C119.1 to prevent accidental disconnection under strain. All harnesses are serialized and validated with mechanical retention and insertion cycle tests before shipment. 

 

How does Frigate mitigate EMC issues in high-frequency signal and power cables?

Frigate uses aluminum-polyester foil with 100% coverage and tinned copper braid shielding exceeding 90% optical density. Shield termination uses full 360° bonding to minimize impedance discontinuities and prevent ground loop formation. Assemblies undergo transfer impedance and shielding attenuation tests per IEC 62153-4-4. This ensures signal stability near switching rectifiers and power conditioning equipment. 

 

What steps does Frigate take to ensure cabling systems meet thermal derating requirements in confined environments?

Frigate models ampacity curves based on conductor size, ambient temperature, and vertical stacking factors using IEC 60287 calculations. Cables are tested under simulated tray and conduit conditions at 70–90°C to validate thermal integrity. LSZH outer jackets ensure flame resistance without compromising flexibility or cooling airflow. These steps enable safe operation even in cable-dense underfloor plenum systems. 

We'd love to Manufacture for you!

Submit the form below and our representative will be in touch shortly.

LOCATIONS

Registered Office

10-A, First Floor, V.V Complex, Prakash Nagar, Thiruverumbur, Trichy-620013, Tamil Nadu, India.

Operations Office

9/1, Poonthottam Nagar, Ramanandha Nagar, Saravanampatti, Coimbatore-641035, Tamil Nadu, India. ㅤ

Other Locations

GENERAL ENQUIRIES

Get Quote
Support All File Formats Including - STEP | STP | SLDPRT | STL | DXF | IPT | X_T | X_B | 3DXML | CATPART | PRT | SAT | 3MF | JT files

Loading....